Advanced Features of Simply Modbus Slave: Tips for Power Users

Simply Modbus Slave: A Beginner’s Guide to Setup and UseSimply Modbus Slave is a widely used, lightweight application that simulates Modbus slave devices (servers) on a computer. It’s useful for testing Modbus masters (clients), validating communications in industrial automation projects, and developing or debugging Modbus-based systems without needing physical devices. This guide walks you through what Simply Modbus Slave does, how Modbus works at a high level, installation and basic setup, common configuration options, typical use cases, troubleshooting tips, and best practices.


What is Modbus, briefly?

Modbus is a simple, open communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with programmable logic controllers (PLCs). It defines a messaging structure for master–slave (client–server) communication. Common Modbus variants include:

  • Modbus RTU (binary serial format)
  • Modbus ASCII (textual serial format)
  • Modbus TCP/IP (Modbus over Ethernet)

Modbus uses function codes to read and write registers and coils. Typical data types are coils (single-bit read/write), discrete inputs (single-bit read-only), holding registers (16-bit read/write), and input registers (16-bit read-only).


What Simply Modbus Slave does

Simply Modbus Slave emulates one or more Modbus slave devices on your PC. It allows you to:

  • Configure slave IDs (unit IDs) and communication parameters.
  • Populate and edit coils, discrete inputs, holding registers, and input registers.
  • Serve data over serial lines (RTU/ASCII) or TCP/IP (Modbus TCP).
  • Log communication for analysis.
  • Test master devices or software by providing predictable responses.

It does not act as a Modbus master — it only responds as slaves. For master-side testing you can use tools like Simply Modbus Master or other Modbus client software.


Installation and system requirements

  • Supported on modern Windows versions (check the vendor site for exact OS compatibility).
  • Download the installer from the official Simply Modbus website.
  • Install using the provided installer; administrator rights may be required to access serial COM ports.

After installation, launch the program from the Start menu or desktop shortcut.


Basic setup: serial (RTU/ASCII)

  1. Open Simply Modbus Slave.
  2. Choose the serial mode (RTU or ASCII) in the connection settings.
  3. Select the correct COM port that’s connected to your Modbus master or USB-to-RS485 adapter.
  4. Set baud rate, data bits, parity, and stop bits to match the master’s configuration. Typical default: 19200, 8, None, 1 (but confirm with your devices).
  5. Set the slave ID (Unit ID) to the value your master will address (commonly 1).
  6. Configure the slave memory ranges: coils, discrete inputs, holding registers, and input registers. Enter initial values for testing.
  7. Click Start (or the equivalent) to begin listening. The program should show communications and log messages when the master polls it.

Basic setup: Modbus TCP

  1. Switch to TCP mode in the connection settings.
  2. Configure the TCP listening port (default Modbus TCP port is 502; some systems use non-privileged higher ports for testing).
  3. Set the slave ID (Unit ID) to match the master’s requests.
  4. Configure register and coil values as needed.
  5. Start the server; the software will listen for TCP connections from Modbus masters and respond accordingly.

Note: On Windows, listening on port 502 may require administrator privileges. If you cannot bind to port 502, pick a high-numbered port (e.g., 1502) and configure the master accordingly.


Editing registers and coils

  • Coils: single-bit writeable values. Use 0/1 or checkboxes where available.
  • Discrete inputs: single-bit read-only values. Set them for the slave to return on read commands.
  • Holding registers: 16-bit read/write registers. Can store integers or raw word data.
  • Input registers: 16-bit read-only registers for analog inputs or sensor data.

Some versions of Simply Modbus Slave allow you to import/export register values from CSV or text files — useful for repeatable test scenarios.


Common testing scenarios

  • Validate master polling: set known register values and confirm the master reads expected data.
  • Test write operations: perform master writes to coils or holding registers and observe the slave’s state updates.
  • Simulate faults: change parity/baudrate or introduce incorrect data to test master error handling.
  • Bulk reads/writes: verify handling of larger register ranges and response times.
  • Simulate multiple slaves: run instances with different unit IDs (or use multi-slave features if supported) to test addressing logic.

Troubleshooting tips

  • No communication: verify COM port, cable wiring (for RS-485 use A/B or +/− and proper termination), and that only one device drives the bus at a time.
  • Wrong data or offsets: confirm whether your master expects zero-based or one-based addressing; Modbus registers are often referenced differently by various tools. If the master reads shifted values, adjust addressing offset in the master or interpret accordingly.
  • Connection refused (TCP): ensure you have rights to bind to the configured port and that no firewall blocks the program. Try a higher port number for testing.
  • CRC/checksum errors: ensure RTU vs ASCII mode and serial settings match between master and slave.
  • Multiple masters or slaves: RS-485 is multi-drop but only one master should initiate at a time; confirm unit IDs do not conflict.

Best practices

  • Use a dedicated test network or isolated serial bus to avoid interfering with production equipment.
  • Keep a library of common register maps and initial CSV files to speed repeated tests.
  • Match timing parameters (timeouts, inter-frame delays) between master and slave to avoid framing errors.
  • Use logging features to capture traffic for analysis and regression testing.
  • When testing Modbus TCP in a corporate network, coordinate with IT to avoid port conflicts and firewall issues.

Example: quick RTU test checklist

  1. Plug USB-to-RS485 adapter; note COM port.
  2. Set Simply Modbus Slave to RTU, COMx, 19200, 8, N, 1.
  3. Set slave ID to 1.
  4. Set holding register 40001 = 123.
  5. Start slave.
  6. On master, read holding register 40001; verify value 123.

Alternatives and complementary tools

  • Simply Modbus Master — companion tool to act as a Modbus master.
  • QModMaster, Modbus Poll — alternative master simulators.
  • Wireshark with Modbus dissector — for TCP traffic analysis.
  • Serial port monitors — to inspect RTU/ASCII exchanges.

Final notes

Simply Modbus Slave is a practical tool to emulate Modbus devices for development, testing, and troubleshooting. Matching communication parameters and addressing conventions between your master and the simulated slave is the most common hurdle; once aligned, the tool enables rapid, repeatable testing without hardware.